Part | Model | Main technical parameters and performance description | |
1 | High voltage generator (imported components) | BWG-50 | External charging general power supply 220VAC. Lithium battery energy, full power can meet 200 times of exposure,remote exposure controller > 50m: Tube Voltage: 40kV~150kV ,Step Length: IkV;: Tube current: 10mA~500mA,load time range: 0.01s~6.3s. current time product range :0.1 mAs〜250 mAs, output nominal electric power :40 kW (400 ma ,100 kv ,0.1 s); inverter input supply voltage :450 VDC/48VDC± 10%; high voltage transformer structure: non-working frequency. |
2 | X ray tube | E7843X | nominal tube voltage :150kV; Focus :0.6/1.2 mm; target angle :12°; anode heat capacity :11 IkJ (150khu); tube sleeve heat capacity :900 KJ (1250khu); anode input power: large focus 50 kW, small focus 22kW; solid filter :1.3mm Al/75kV; Rotating anode, rotational speed :3200 rpm.. |
3 | Beam limiter | BRC-20 | mmAl/75kV;1.0
manual control; LED visual field indicator light; 360° Adjustable rotation angle. |
4 | Amorphous silicon plate Detector | Care View
1800CW |
Cesium iodide amorphous silicon plate. Pixel matrix: > 2816×2816; imaging area: 17×17 “pixel size: < 154um m, spatial resolution: 3.51p/mm, AD conversion 16bits; MTF: > 60% @ lip / mm > 20% @ 3Ip / mm DQE: (@ rqa5, 30 卩 Gy) > 60% @ Olp / mm > 15% @ 3Ip / mm dynamic range: > 80dB; imaging time: original image output time < 3 seconds, after loading software processing should be about 8 seconds |
5 | Mobile frame | Main wheel in front design; stable center of gravity; small turning radius; light motion control; easy to push by manpower; electromagnetic locking and fixation of cross arm during trolley motion; cross arm: front and back movement range N 250mm, up and down movement range N 1200mm; ball tube can rotate vertically + 90 ° , – 10 0 and horizontally ± 180 0 ; head with locking mechanism can be locked at any angle. The column can be kneaded at +180 ° , and the electromagnetic brake with power loss can be locked and fixed; | |
6 | DR image processing Software | PICKE-DR | DR diagnostic software:
DICOM3.0 criteria, pre-selection tips for cast position; preset of image brightness / contrast, window width / window position; preset of organization equalization technology; preset of image enhancement and sharpening technology; image segmentation, transmission, printing, etc. |
7 | Image
Acquisition Station |
BWS-20 | Minimum performance requirements for display: screen range :17″; resolution :>1280x 1024
Minimum computer performance requirements: CPU>i3 hard disk >500 G memory >4 G; |
8 | Documents | Registration Document, Specification and Product Certificate |
Digital Mobile Radiography X-ray System (Picke 1800 DRM)
SUPPORT PURCHASE
- Hotline: 0243.202.8881
- Email: phanhai_pan@szclwell.com
(Hỗ trợ 24/7)
- Hotline: 0243.202.8881
- Email: phanhai_pan@szclwell.com
(Hỗ trợ 24/7)
Category: Medical equipment
Be the first to review “Digital Mobile Radiography X-ray System (Picke 1800 DRM)” Cancel reply
Related products
Medical equipment
Reviews
There are no reviews yet.